<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>500</ErrorNumber>
<ErrorFamily>Miscellaneous</ErrorFamily>
<ErrorMessage>
MISC: Temperature log: Engine = &lt;Celcius x 10&gt;  Leadscrew = &lt;Celcius x 10&gt;
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
This message does not indicate an error.  It is reported at regular intervals (currently every 30 minutes) to
the workstation (and diagnostic monitor).  The temperature is given in Celcius times 10 (i.e. 21.6 degrees is
reported as 216).  If either temperature is reported as 0, the corresponding temperature sensor is
malfunctioning or disconnected.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
None required.  The workstation debug log should contain one of these temperature logs every 30 minutes.
</text></DescriptionText>
</OperatorAction>
<Cause>
Reported every 30 minutes.
</Cause>